1. All 3M Products
  • 3M™ LifeASSURE™ PDA Series Filter Capsule
  • 3M™ LifeASSURE™ PDA Series Filter Capsule

    Products
    • Robust double membrane layer filter construction. Exceptionally high contaminant capacity and fast flow rates for long on-stream life and maximum economy
    • Hydrophilic asymmetric polyethersulfone membrane enables wet out in aqueous solutions for integrity testing
    • Validated 0.2 μm absolute-rated membrane, reliable for sterilising filtration
    • Capsule filters are available in both gamma compatible and sterile formats to eliminate cleaning and cleaning validation step associated with stainless steel housings for maximal ease-of-use
     More...
    Overall Length (Metric)
    Overall_Length_Metric
    Products Available
     Overall Length (Metric)
    All Models
    Close
    Specifications
    Applications
    Plasma Fractionation, Vaccines
    Brand
    LifeASSURE™
    End Modification
    1.5" Sanitary Fitting
    Factory Integrity Tested
    Yes
    Filter Material
    Polyether Sulfone Membranes
    Filter Type
    Surface
    Formulation
    Pharmaceutical
    Gamma Compatible
    Yes
    Gasket/O-ring Material
    Silicone
    Industries
    Life Sciences
    Maximum Operating Temperature (Celsius)
    40 Degree Celsius
    Micron Rating
    0.2 μm
    Overall Length (Metric)
    12.7 cm, 25.4 cm, 6.35 cm
    Pleat Type
    Advanced Pleat Technology
    Product Form
    Cartridge
    Product Series
    PDA
    Series
    LifeASSURE™ PDA Series
    Details

    3M™ LifeASSURE™ PDA series filters combine two asymmetric polyethersulfone (PES) membrane layers with Advanced Pleat Technology design. This combination results in a robust filter that is optimised for both high throughput and fast flow applications while offering 0.2 μm absolute rated filtration for sterilising performance. The unique hydrophilic polyethersulfone membrane wets easily for integrity testing and is ideal for applications where low protein binding is critical.

    • Robust double membrane layer filter construction. Exceptionally high contaminant capacity and fast flow rates for long on-stream life and maximum economy
    • Hydrophilic asymmetric polyethersulfone membrane enables wet out in aqueous solutions for integrity testing
    • Validated 0.2 μm absolute-rated membrane, reliable for sterilising filtration
    • Capsule filters are available in both gamma compatible and sterile formats to eliminate cleaning and cleaning validation step associated with stainless steel housings for maximal ease-of-use
    • Advanced Pleat Technology construction. Allows maximum fluid and contaminant access to filter surface area for highest throughput
    • 100% Integrity tested prior to release to ensure consistent conformance to specification
    • 21 CFR compliant materials of construction, USP Biological Reactivity Test for Plastics Class VI, Validation Guide and Drug Master File (DMF)